Sexually Transmitted Bacteria Reference Laboratory, Health Protection Agency, Centre for Infections, 61 Colindale Ave, London NW9 5HT, UK
Correspondence
Sarah Alexander
sarah.alexander{at}hpa.org.uk
Received 20 January 2008
Accepted 24 April 2008
Abbreviations: LGV, lymphogranuloma venereum; MSM, men who have sex with men; STBRL, Sexually Transmitted Bacteria Reference Laboratory; UNG, uracil glycolase.
| INTRODUCTION |
|---|
|
|
|---|
LGV is caused by specific serovars of Chlamydia trachomatis (L1, L2 and L3) and these strains are associated with a more chronic and invasive infection than other serovars. Although LGV symptoms can vary according to site of entry and stage of infection, genital ulceration and inguinal lymphadenopathy are the classical presentations of this disease. However, during the recent European MSM outbreak, anorectal symptoms were the most common presentation, making syndromic management problematic (van de Laar, 2006; Richardson & Goldmeier, 2007). LGV infection is also more complex than standard C. trachomatis infection, with patients requiring an extended course of therapy when compared with infection with serovars D–K. Because of this, the accurate laboratory diagnosis of LGV serovars of C. trachomatis is essential (BASHH, 2006; McLean et al., 2007).
The laboratory identification of LGV can be problematic, as routine culture of C. trachomatis for diagnostic purposes has largely been replaced with nucleic acid amplification techniques; consequently, traditional serotyping methods are now redundant. Two main molecular methods that enable the identification of LGV biovars of C. trachomatis have been described: (i) PCR amplification of a 1.1 kb region of the outer-membrane I (ompI) gene followed by restriction enzyme digestion (ompI RFLP-PCR; Lan et al., 1993, 1994); and (ii) real-time PCR targeting a 36 bp deletion present within the polymorphic membrane protein H (pmpH) gene of LGV-associated serovars (pmpH real-time PCR; Morre et al., 2005).
Clinical specimens referred to the Sexually Transmitted Bacteria Reference Laboratory (STBRL; London, UK) for LGV diagnosis were examined initially using a combination of a plasmid-based real-time PCR that detects all C. trachomatis serovars and ompI RFLP-PCR. These specimens were then examined retrospectively using the LGV-specific pmpH real-time PCR. Here, we report the first comparative data for the two major methods available for the detection of LGV from clinical specimens.
| METHODS |
|---|
|
|
|---|
A range of specimens were received, including fresh dry swabs, unprocessed swabs in transport buffer and residual processed material from nucleic acid amplification techniques. Dry swabs were hydrated with 500 µl PBS and agitated on an orbital shaker at 150 r.p.m. for 1 h.
DNA extraction. DNA extractions were performed using one of three methods: (i) manual extraction using a QIAamp Viral RNA Mini kit (Qiagen); (ii) automated extraction using a Corbett DNA X-Tractor with a Macherey-Nagel blood extraction kit; or (iii) MagNA Pure automated extraction (Roche). The three different methods of DNA extraction were employed to cope with increasing levels of specimen referrals, with each representing an advancement in automation. All extractions were performed according to the manufacturer's instructions and each clinical specimen was extracted using only a single DNA extraction method.
C. trachomatis detection. The Chlamydia status of all specimens was determined using the method of Chen et al. (2007). The PCR contained primers targeting an 88 bp region of the C. trachomatis cryptic plasmid and primers targeting the human RNase P gene, which acted as an internal control. All reactions were performed on a Corbett RotorGene-3000. Each 25 µl reaction contained the following primers and reagents: 200 nM CTF-008 (5'-GGATTGACTCCGACAACGTATTC-3'), 300 nM CTR-009 (5'-ATCATTGCCATTAGAAAGGGCATT-3'), 200 nM CTP-010 (5'-FAM-TTACGTGTAGGCGGTTTAGAAAGCGG-BHQ1-3'), 80 nM RNPF-003 (5'-AGATTTGGACCTGCGAGCG-3'), 80 nM RNPR-002 (5'-GAGCGGCTGTCTCCACAAGT-3'), 80 nM RNPP-001 (5'-CY5-TTCTGACCTGAAGGCTCTGCGCG-BHQ3-3'), 200 µM dATP, 200 µM dCTP, 200 µM dGTP, 400 µM dUTP, 1x PCR buffer (Applied Biosystems), 4 mM MgCl2, 5 U AmpliTaq Gold polymerase (Applied Biosystems), 0.5 U uracil glycolase (UNG) and 10 µl DNA template. Reaction conditions were: 2 min at 50 °C (denaturation of UNG) and 10 min at 95 °C (hot-start Taq activation), followed by 45 cycles of 25 s at 95 °C (denaturation) and 1 min at 60 °C (combined annealing and extension). In instances where the specimens were found to be negative for C. trachomatis, their negative status was confirmed using an Artus C. trachomatis Real-Art kit. In instances where the Artus kit and the in-house plasmid-based PCR produced positive results after 40 cycles, the specimen was described as equivocal.
Genotyping methods by RFLP. Genotyping of the samples positive for C. trachomatis was performed using the methods of Lan et al. (1993, 1994). Briefly, a 1.1 kb section of the ompI gene of C. trachomatis was amplified by nested PCR. The first round contained primers NLO (5'-ATGAAAAAACTCTTGAAATCG-3') and NRO (5'-CTCAACTGTAACTGCGTATTT-3'). The second round contained primers PCTM3 (5'-TCCTTGCAAGCTCTGCCTGTGGGGAATCCT-3') and CT4 (5'-CCGCAAGATTTTCTAGATTTCATCTTGT-3'). All PCR runs contained positive controls for serovars L1, L2 and L3 and a negative control. Amplification was confirmed using a DNA7500 LabChip on an Agilent Bioanalyser. Products were then digested for 2 h with AluI at 37 °C and separated on a DNA7500 LabChip. Digestion patterns were compared with those obtained for controls L1, L2 and L3. Samples with a restriction digest pattern giving an L3 profile were additionally digested using EcoRI and DdeI at 37 °C for 2 h to differentiate between serovars H, I and L3. Samples were assigned as being LGV-associated or non-LGV-associated on the basis of their restriction digest profile.
pmpH real-time PCR. The LGV-specific pmpH real-time PCR assay was performed retrospectively on specimens that had been examined previously by ompI RFLP-PCR. The assay was carried out on a Rotor-Gene 3000 PCR instrument according to the methods of Morre et al. (2005). Each 20 µl reaction contained the following: 250 nM LGV-F (5'-CTGTGCCAACCTCATCATCAA-3'), 250 nM LGV-R (5'-AGACCCTTTCCGAGCATCACT-3'), 500 nM LGV-Probe (5'-6-FAM-CCTGCTCCAACAGT-MGB-3'), 200 µM dATP, 200 µM dCTP, 200 µM dGTP, 400 µM dUTP, 1x PCR buffer (Applied Biosystems), 4 mM MgCl2, 5 U AmpliTaq Gold polymerase, 0.5 U UNG and 5 µl DNA template. Reaction conditions were: 2 min at 50 °C (denaturation of UNG) and 10 min at 95 °C (hot-start Taq activation), followed by 45 cycles of 15 s at 95 °C (denaturation) and 1 min at 60 °C (combined annealing and extension).
Where ompI RFLP-PCR and pmpH real-time PCR produced discordant results, both tests were repeated, if sufficient sample was available, to confirm the results in an attempt to resolve the discordant status.
| RESULTS |
|---|
|
|
|---|
|
Fourteen specimens were found to be positive using the pmpH real-time PCR method but non-LGV-associated using ompI RFLP-PCR. It is unlikely that false-positive pmpH real-time PCR results can explain these discrepancies, as repeat testing of ten of these specimens confirmed that these samples were reproducibly positive by pmpH real-time PCR (the four remaining specimens had insufficient volume for repeat testing). It should be noted that the specimens examined in this study were obtained from very high-risk patients and therefore the possibility of mixed-serovar C. trachomatis infections cannot be overlooked. This could provide a highly likely explanation for these discrepant results, as the real-time PCR method only requires one LGV pmpH target to generate a positive result, whereas the ompI RFLP-PCR would generate either a mixed profile or a profile of the most abundant C. trachomatis serovar, which could have resulted in a result for non-LGV-associated serovar of C. trachomatis being generated. Again, it is also possible that the subjective nature of RFLP-PCR profiles could have resulted in some weak or partially digested LGV profiles being misidentified as non-LGV-associated serovars.
The remaining three clinical specimens produced discrepant results when examined by pmpH real-time PCR and these could not be resolved. For all three specimens, two DNA extractions were performed from the original swab transport medium because the ompI gene had failed to amplify in the initial RFLP-PCR. When retrospectively performing the pmpH real-time PCR on both extractions from all three specimens, discordant results were produced, with one extraction producing a positive result and one producing a negative result. Attempts were made to resolve the discordant status of two of these specimens by performing a fresh DNA extraction (one specimen had insufficient volume for a repeat extraction); however, both specimens had completely degraded.
| DISCUSSION |
|---|
|
|
|---|
This study compared two methods for the detection of LGV from clinical samples. Whilst both methods showed high levels of concordance (94.7 %), they were found to differ in terms of technical complexity. The greater sensitivity, shorter turnaround time and lower technical requirement of the pmpH real-time PCR test would make it the test of choice for diagnostic use. The ompI RFLP-PCR is not a diagnostic test but rather a C. trachomatis genotyping method, which enables serovar-level identification of a specific clinical specimen. However, this method lacks sensitivity, has a lengthy turnaround time and requires both experienced staff and specialist equipment, and therefore is almost exclusively confined to specialized centres. In the UK, all LGV infection is detected at a central facility (STBRL), where currently the LGV testing algorithm is to test any referred specimen for LGV using the more sensitive and rapid pmpH real-time PCR. All pmpH real-time PCR-positive specimens are then examined further using the ompI RFLP-PCR to identify the precise serovar of LGV responsible and to confirm the original pmpH result.
Ultimately, the detection of a LGV-positive clinical specimen using either of the methods examined in this study will always be technically demanding, as specimens first require a primary screen with a C. trachomatis diagnostic test. Such an approach has been problematic historically, as not all commercial C. trachomatis platforms are approved by the Food and Drug Administration for the examination of rectal specimens, although recent data suggest that these platforms exhibit high specificity when presented with these specimens (Alexander et al., 2007). In addition, whilst a recent real-time PCR method has been described that enables the simultaneous detection of both C. trachomatis serovars and L2 strains specifically, such a method would clearly miss LGV infections caused by L1 and L3 serovars (Halse et al., 2006).
LGV infection remains an important threat to the health of high-risk MSM in Europe, with 492 cases of LGV confirmed within the UK to date (Jebbari et al., 2007). In the UK – unlike other European countries – the case definition of a confirmed LGV infection is one that has been detected in the laboratory using solely molecular methods. In this study, two methods were compared for the detection of LGV from clinical samples, both of which were found not only to have a high concordance (94.7 %), but also to be complementary, and could be used in an integrated way to aid LGV detection.
| ACKNOWLEDGEMENTS |
|---|
| REFERENCES |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| INT J SYST EVOL MICROBIOL | J MED MICROBIOL | MICROBIOLOGY | J GEN VIROL | ALL SGM JOURNALS |