J Med Microbiol Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Durand, F.
Right arrow Articles by Pelloux, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Durand, F.
Right arrow Articles by Pelloux, H.
Agricola
Right arrow Articles by Durand, F.
Right arrow Articles by Pelloux, H.
J Med Microbiol 54 (2005), 1115; DOI: 10.1099/jmm.0.46067-0
© 2005 Society for General Microbiology
ISSN 0022-2615

Invalid result of Plasmodium falciparum malaria detection with the BinaxNOW Malaria rapid diagnostic test

François Durand1, Odile Faure1, Jean-Paul Brion2 and Hervé Pelloux3

1,2,3All Service de Parasitologie-Mycologie Médicale1, Service des Maladies Infectieuses2 and Service de Parasitologie-Mycologie Médicale3, Centre Hospitalier Universitaire de Grenoble, 38043 Grenoble Cedex 09, France

Correspondence: François Durand (frdurand{at}chu-grenoble.fr)


Malaria is endemic in many tropical countries and causes the deaths of at least 1 000 000 people per year. People who live in non-endemic countries are also concerned by fatal cases when they travel to endemic areas for vacations or business (Ryan & Kain, 2000). Mainly, malaria diagnoses are made after return from travel and require biological tests. Besides blood smears, which remain the reference for malaria diagnosis, new rapid diagnostic tests (RDTs) are available. BinaxNOW Malaria (Binax) is an immunochromatographic test (ICT) that detects malarial antigens in patient blood (Murray et al., 2003). Both pan-specific (aldolase) and Plasmodium falciparum-specific (histidine-rich protein 2, HRP-2) antigens can be detected by this test with high sensitivity concerning P. falciparum detection. Many evaluation studies comparing these RDTs with traditional (e.g. thin or thick blood smear) or accurate (e.g. PCR) methods have been published. Sources of false positive (rheumatoid factor) or false negative (low parasitaemia) results with these test are known, but invalid cases have never been pointed out to our knowledge (Murray et al., 2003).

Each year, 200 malaria tests in blood samples are performed in our laboratory (located in a teaching hospital of a non-endemic country), and BinaxNOW Malaria ICT has now been routinely used for 2 years. We report here the case of a patient in whom the diagnosis of malaria was not possible with the BinaxNOW Malaria test. Severe P. falciparum malaria was diagnosed for a patient 5 days before his hospitalization in our teaching hospital. Quinine treatment was started 4 days before his admission. We received a whole blood sample of this patient in an EDTA tube on the day of his admission to control parasitaemia. In this sample, no parasite was seen by examination of thin blood smear nor with the Quantitative Buffy Coat method (QBC, Becton Dickinson). Antigen detection of plasmodia was also performed on this sample with the BinaxNOW Malaria ICT used strictly according to the manufacturer's instructions. The HRP-2 line (T1) was positive according to the clinical history of the patient but the test could not be validated because of the non-appearance of the control line (C) even when the assay was performed with different batches of the test by different experienced practitioners (Fig. 1).



View larger version (82K):
[in this window]
[in a new window]
 
Fig. 1. BinaxNOW Malaria ICT assay performed 4 days after the beginning of the quinine treatment in a case of P. falciparum malaria. The HRP-2 P. falciparum-specific line (T1) is positive but no control line (C) becomes visible. Assays were performed three times by different experienced practitioners with different batches of the test.

 

According to the manufacturer's instructions, the control line should always appear at the top of the ICT in order to validate the assay. We hypothesize that an inhibitor is present in the blood of this patient, preventing high-quality development of the assay. In order to prove this, we diluted the blood of the patient with isotonic NaCl solution (9 {per thousand}). We then searched for the presence of a human anti-mouse antibody (HAMA) known to potentially modify immunological tests (Thorpe et al., 2003), since mouse immunoglobulins are utilized in this ICT. The 1/8 dilution of the sample made the control line become visible with the positive HRP-2 line still present, while the 1/16 dilution made the positive HRP-2 line become undetectable with the control line still positive. This experience suggests that an inhibitor was present in the patient's blood, but no HAMA was detected in the serum of the patient (HAMA-Elisa Medac, Medac Diagnostika).

Such a case of an invalid result with BinaxNOW Malaria ICT has never been published to our knowledge even though multiple studies have evaluated this test. Thus, patients presenting with a circulating inhibitor might not be common; however, the increase in the number of travellers from non-endemic countries to endemic areas and the increasing use of RDTs as diagnostic tools for malaria require us to consider the possibility of observing invalid results.


    References
 TOP
 References
 

  • Murray, C. K., Bell, D., Gasser, R. A. & Wongsrichanalai, C. (2003). Rapid diagnostic testing for malaria. Trop Med Int Health 8, 876–883.[CrossRef][Medline]

  • Ryan, E. T. & Kain, K. C. (2000). Health advice and immunization for travellers. N Engl J Med 342, 1716–1725.[Free Full Text]

  • Thorpe, S. J., Turner, C., Health, A., Feavers, I., Vatn, I., Natvig, J. B. & Thompson, K. M. (2003). Clonal analysis of a human antimouse antibody (HAMA) response. Scand J Immunol 57, 85–92.[Medline]




    This article has been cited by other articles:


    Home page
    Am J Trop Med HygHome page
    C. Wongsrichanalai, M. J. Barcus, S. Muth, A. Sutamihardja, and W. H. Wernsdorfer
    A Review of Malaria Diagnostic Tools: Microscopy and Rapid Diagnostic Test (RDT)
    Am J Trop Med Hyg, December 1, 2007; 77(6_Suppl): 119 - 127.
    [Abstract] [Full Text] [PDF]


    This Article
    Right arrow Full Text (PDF)
    Right arrow Alert me when this article is cited
    Right arrow Alert me if a correction is posted
    Services
    Right arrow Email this article to a friend
    Right arrow Similar articles in this journal
    Right arrow Similar articles in PubMed
    Right arrow Alert me to new issues of the journal
    Right arrow Download to citation manager
    Right arrow reprints & permissions
    Citing Articles
    Right arrow Citing Articles via HighWire
    Right arrow Citing Articles via CrossRef
    Right arrow Citing Articles via Google Scholar
    Google Scholar
    Right arrow Articles by Durand, F.
    Right arrow Articles by Pelloux, H.
    Right arrow Search for Related Content
    PubMed
    Right arrow PubMed Citation
    Right arrow Articles by Durand, F.
    Right arrow Articles by Pelloux, H.
    Agricola
    Right arrow Articles by Durand, F.
    Right arrow Articles by Pelloux, H.


    HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
    INT J SYST EVOL MICROBIOL J MED MICROBIOL MICROBIOLOGY J GEN VIROL ALL SGM JOURNALS