J Med Microbiol Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jmm.0.010587-0v1
58/7/878    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Google Scholar
Right arrow Articles by Habbal, W.
Right arrow Articles by Gärtner, B. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Habbal, W.
Right arrow Articles by Gärtner, B. C.
Agricola
Right arrow Articles by Habbal, W.
Right arrow Articles by Gärtner, B. C.
J Med Microbiol 58 (2009), 878-883; DOI: 10.1099/jmm.0.010587-0
© 2009 Society for General Microbiology
ISSN 0022-2615

Comparative evaluation of published cytomegalovirus primers for rapid real-time PCR: which are the most sensitive?

Wafa Habbal1, Fawza Monem1 and Barbara C. Gärtner2

1 Clinical Laboratories Department, Al-Assad University Hospital, Damascus University, PO Box 10769, Damascus, Syria

2 Department of Virology, University of Saarland Medical School, D-66421 Homburg/Saar, Germany

Correspondence
Barbara C. Gärtner
barbara.gaertner{at}uks.eu

Received February 25, 2009
Accepted March 16, 2009

Standardization of human cytomegalovirus (CMV) PCR is highly recommended. As primer design is essential for PCR sensitivity, this study evaluated all published CMV primer pairs to identify the most sensitive for single-round real-time PCR. PubMed (1993–2004) was searched for original papers aimed at CMV PCR. Fifty-seven papers were identified revealing 82 different primer pairs. Of these, 17 primer sets were selected for empirical study, as they were either used in real-time PCR or were evaluated comparatively by conventional PCR. After optimizing the PCR conditions, these primer sets were evaluated by real-time PCR using a SYBR Green format. Analytical sensitivities were assessed by testing the reference standard CMV strain AD169. A BLAST search was performed to identify mismatches with published sequences. Additionally, 60 clinical samples were tested with the three primer sets showing highest analytical sensitivity and the best match to all CMV strains. Three primer sets located in the glycoprotein B (UL55) gene region were found to be the most sensitive using strain AD169. However, two of these showed a considerable number of mismatches with clinical isolates in a BLAST search. Instead, two other pairs from the lower matrix phosphoprotein (UL83) gene and DNA polymerase (UL54) gene showed reasonable sensitivity and no mismatches with clinical isolates. These three pairs were further tested with clinical samples, which indicated that the two primer sets from UL55 and UL54 were the most sensitive. Interestingly, the analytical sensitivity of the PCR was inversely correlated with the size of the PCR product. In conclusion, these two primer pairs are recommended for a standardized, highly sensitive, real-time PCR.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
INT J SYST EVOL MICROBIOL J MED MICROBIOL MICROBIOLOGY J GEN VIROL ALL SGM JOURNALS
Copyright © 2009 Society for General Microbiology.