J Med Microbiol International Journal of Systematic and Evolutionary Microbiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Google Scholar
Right arrow Articles by Wu, F.-B.
Right arrow Articles by Zhou, Z.-X.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, F.-B.
Right arrow Articles by Zhou, Z.-X.
Agricola
Right arrow Articles by Wu, F.-B.
Right arrow Articles by Zhou, Z.-X.
J Med Microbiol 57 (2008), 947-953; DOI: 10.1099/jmm.0.47835-0
© 2008 Society for General Microbiology
ISSN 1473-5644

Double-antigen sandwich time-resolved immunofluorometric assay for the detection of anti-hepatitis C virus total antibodies with improved specificity and sensitivity

Feng-Bo Wu1,{dagger}, Hai-Qiao Ouyan1, Xiao-Yan Tang1 and Zhen-Xian Zhou2,{dagger}

1 Research & Development Department, SYM-BIO Life-Science Co. Ltd, Tai-Cang City, Jiang-Su Province 215400, PR China

2 Clinical Laboratory, Nanjing Second Hospital, Nanjing City 210003, PR China

Correspondence
Feng-Bo Wu
gaoweiwuli{at}21cn.com

Received 20 December 2007
Accepted 24 March 2008


Current anti-hepatitis C virus (HCV) antibody screening immunoassays are routinely based on an indirect format. Although their use for anti-HCV antibody detection has achieved a very high specificity and sensitivity, false-positive results are still a problem especially among populations with a low prevalence of HCV infection. One strategy to obviate this problem is to adapt the assay from an indirect format to a double-antigen sandwich one to further improve its specificity. In this study, a double-antigen sandwich time-resolved immunofluorometric assay (DAS-TRIFMA) has been developed to detect total anti-HCV antibodies based on biotin–streptavidin interaction. For comparison, 1025 samples were analysed by the DAS-TRIFMA and three indirect anti-HCV antibody detection methods. For samples with discordant results, PCR-ELISA and Inno-LIA were employed as supplementary assays to analyse the presence of HCV antibodies. With regard to the 1025 clinical samples, the overall concordance between the DAS-TRIFMA and the three indirect methods was 99.41, 98.93 and 98.93 % for Ortho ELISA 3.0, WAT ELISA and I-TRIFMA, respectively. The specificity/sensitivity of the DAS-TRIFMA, Ortho HCV ELISA 3.0, WAT HCV ELISA and I-TRIFMA were 100/99.09, 99.34/98.18, 99.23/97.27 and 99.01 %/98.18 %, respectively. The DAS-TRIFMA was able to detect HCV antibodies at a concentration about 1/10 of that detectable by indirect methods. From the obtained results and their comparison, it is concluded that the DAS-TRIFMA is a more specific and reliable method for screening anti-HCV antibodies, and weakly positive S/Co values by the DAS-TRIFMA were more predictive of HCV infection than those by indirect methods.


Abbreviations: DAS-TRIFMA, double-antigen sandwich time-resolved immunofluorometric assay; I-TRIFMA, indirect TRIFMA.

{dagger}These authors contributed equally to this work.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
INT J SYST EVOL MICROBIOL J MED MICROBIOL MICROBIOLOGY J GEN VIROL ALL SGM JOURNALS
Copyright © 2008 Society for General Microbiology.