|
|
||||||||
1Chemotherapy Division, Mitsubishi Kagaku Bio-Clinical Laboratories Inc., 3-30-1 Shimura, Itabashi-ku, Tokyo 174-8555, Japan 2Department of Microbiology, Toho University of Medicine, Tokyo, Japan
Correspondence Intetsu Kobayashi mbc-ka{at}sa2.so-net.ne.jp
Received June 3, 2004
Accepted August 17, 2004
We evaluated the automated VITEK 2 system (bioMérieux) for antimicrobial susceptibility testing of vancomycin-resistant Enterococcus (VRE). The results obtained with the VITEK 2 system were compared to those obtained using two NCCLS reference methods. The VITEK 2 system produced MICs for penicillin G, erythromycin and vancomycin that were very similar to those of the reference agar-dilution test with all results being within a twofold dilution. When MICs of teicoplanin for these isolates were measured by the agar-dilution method and VITEK 2 system, there was one very major error and seven minor errors. There were no major errors for any of the antibiotics tested. When the results obtained by the micro broth-dilution method were compared with those obtained by the VITEK 2 system, there was one very major error for teicoplanin by the VITEK 2 system, as was the case with the agar-dilution method. There were two minor errors for erythromycin and seven minor errors for teicoplanin. There were no major errors for any of the antibiotics tested. The 35 VRE strains identified phenotypically by the VITEK 2 Advanced Expert System included nine of Enterococcus faecalis and 23 of Enterococcus faecium. Neither Enterococcus avium nor Enterococcus hirae were identified. A total of 32 phenotypes were classified into 22 VanA and 10 VanB strains. PCR genotyping demonstrated 23 vanA+ and nine vanB+ strains. There were differences between the VITEK 2 system results and those of PCR. Overall, 54.3 % of the test results were obtained within 7 h. All MIC values for the 35 VRE isolates were determined within 13 h of completing incubation. The VITEK 2 system is a simple method for accurately detecting vancomycin-resistant strains of Enterococcus and can be used to rapidly determine MICs.
This article has been cited by other articles:
![]() |
M. Abele-Horn, L. Hommers, R. Trabold, and M. Frosch Validation of VITEK 2 Version 4.01 Software for Detection, Identification, and Classification of Glycopeptide-Resistant Enterococci J. Clin. Microbiol., January 1, 2006; 44(1): 71 - 76. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| INT J SYST EVOL MICROBIOL | J MED MICROBIOL | MICROBIOLOGY | J GEN VIROL | ALL SGM JOURNALS |