J Med Microbiol Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leonardi, G. P.
Right arrow Articles by Szabo, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leonardi, G. P.
Right arrow Articles by Szabo, K.
Agricola
Right arrow Articles by Leonardi, G. P.
Right arrow Articles by Szabo, K.

The Journal of Medical Microbiology, Vol 44, Issue 2 147-150, Copyright © 1996 by Society for General Microbiology


JOURNAL ARTICLE

Evaluation of verification assays in EIA specimens presumptively positive for Chlamydia trachomatis

G. P. Leonardi, A. M. Stavroulakis, J. Cruz and K. Szabo
Department of Pathology, Nassau County Medical Center, East Meadow, New York, USA.

Verification of specimens positive for Chlamydia trachomatis by enzyme immunoassay (EIA) has been recommended when testing low prevalence populations. This study compared direct fluorescent antibody (DFA) and blocking antibody (BLA) verification assays in specimens presumptively positive for C. trachomatis by the Syva Microtrak II EIA. Of 1785 specimens originally tested by EIA, 96 were presumptively positive for C. trachomatis. Verification assays were concordant in 86 specimens (69 positive, 17 negative); nine of the remaining samples gave positive results in a second EIA and one was unresolved. Both verification assays gave some false-negative results. When initial EIA absorbance values were correlated with verified results, all EIA false positive results had absorbances in the low range (less than a three-fold increase over assay cut-off values). Verification of EIA results by both DFA and BLA was effective in detecting false positive results, but confining verification to low-value positive specimens could be considered for cost effective C. trachomatis testing.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
INT J SYST EVOL MICROBIOL J MED MICROBIOL MICROBIOLOGY J GEN VIROL ALL SGM JOURNALS
Copyright © 1996 Society for General Microbiology.